Falownik trójfazowy Uwe=3x400V AC, Iwe=35A, Uwy=3x400V AC, Iwy=32A, Pmax=15kW
Information | Value |
---|---|
Supplier | F&F Filipowski Spółka Komandytowa |
Series | FA |
Symbol | FA-3X150 |
GTIN(EAN) | 5908312598411 |
Price unit | piece |
Catalog price | 6 434,13 zł (5 231,00 zł + 23% VAT) |
The given prices do not constitute an offer within the meaning of the Civil Code. The purchase prices of a given item may differ from those displayed.
Promotions related to this product
Description:
Napięcie wejściowe 3 x 400 V Prąd wejściowy 35 A Napięcie wyjściowe 3 x 400 V Prąd wyjściowy 32 A Maksymalna moc silnika 15 kW Długość L 360 mm Szerokość W 220 mm Wysokość H 210 mm Temperatura pracy -10÷40°C
Additional features:
Information | Value |
---|---|
Gross weight: | 990 g |
ETIM class: | Frequency converter =< 1 kV |
Mains voltage: | 380 - 415 V |
Mains frequency: | 50/60 Hz |
Number of phases input: | 3 |
Number of phases output: | 3 |
Max. output frequency: | 3200 Hz |
Nominal output current I2N: | 32 A |
Max. output at quadratic load at rated output voltage: | 15 kW |
Max. output at linear load at rated output voltage: | 15 kW |
Relative symmetric net frequency tolerance: | 5 % |
Relative symmetric net voltage tolerance: | 10 % |
With control element: | yes |
Application in industrial area permitted: | yes |
Application in domestic- and commercial area permitted: | yes |
Supporting protocol for TCP/IP: | no |
Supporting protocol for PROFIBUS: | no |
Supporting protocol for CAN: | no |
Supporting protocol for INTERBUS: | no |
Supporting protocol for ASI: | no |
Supporting protocol for KNX: | no |
Supporting protocol for Modbus: | yes |
Supporting protocol for Data-Highway: | no |
Supporting protocol for DeviceNet: | no |
Supporting protocol for SUCONET: | no |
Supporting protocol for LON: | no |
Supporting protocol for PROFINET IO: | no |
Supporting protocol for PROFINET CBA: | no |
Supporting protocol for SERCOS: | no |
Supporting protocol for Foundation Fieldbus: | no |
Supporting protocol for EtherNet/IP: | no |
Supporting protocol for AS-Interface Safety at Work: | no |
Supporting protocol for DeviceNet Safety: | no |
Supporting protocol for INTERBUS-Safety: | no |
Supporting protocol for PROFIsafe: | no |
Supporting protocol for SafetyBUS p: | no |
Supporting protocol for other bus systems: | no |
Number of HW-interfaces industrial Ethernet: | 0 |
Number of interfaces PROFINET: | 0 |
Number of HW-interfaces RS-232: | 0 |
Number of HW-interfaces RS-422: | 0 |
Number of HW-interfaces RS-485: | 1 |
Number of HW-interfaces serial TTY: | 0 |
Number of HW-interfaces USB: | 0 |
Number of HW-interfaces parallel: | 0 |
Number of HW-interfaces other: | 0 |
With optical interface: | no |
Integrated breaking resistance: | yes |
4-quadrant operation possible: | no |
Type of converter: | U converter |
Degree of protection (IP): | IP20 |
Height: | 360 mm |
Width: | 220 mm |
Depth: | 210 mm |
Buy online
Wholesalers below does not have this product in their warehouses. You can anyway contact them and order it.
Order
Wholesaler
Address
Distance
Actions
Szaflary,
ul. Zakopiańska 18
Distance:
Limanowa,
ul. Tarnowska 9D
Distance:
Gniezno,
ul. Słoneczna 40a
Distance:
Additional information:
Information | Value |
---|---|
Updated: | 2024-12-04 00:03:02 |
Files to download: | |
External links: |