DE11-122D3FN-N20N DE11, 0,37kW, 1-faz. 230V, filtr RFI, CANopen
Information | Value |
---|---|
Supplier | EATON Electric Sp. z o.o. (MOELLER) |
Symbol | 180651 |
GTIN(EAN) | 4015081758166 |
Price unit | piece |
Catalog price | 845,38 zł (687,30 zł + 23% VAT) |
The given prices do not constitute an offer within the meaning of the Civil Code. The purchase prices of a given item may differ from those displayed.
Additional features:
Information | Value |
---|---|
Net weight: | 1,04 kg |
ETIM class: | Frequency converter =< 1 kV |
Mains voltage: | 200 - 240 V |
Mains frequency: | 50/60 Hz |
Number of phases input: | 1 |
Number of phases output: | 3 |
Max. output frequency: | 300 Hz |
Max. output voltage: | 250 V |
Nominal output current I2N: | 2.3 A |
Max. output at quadratic load at rated output voltage: | 0.37 kW |
Max. output at linear load at rated output voltage: | 0.37 kW |
Relative symmetric net frequency tolerance: | 10 % |
Relative symmetric net voltage tolerance: | 10 % |
Number of analogue outputs: | 0 |
Number of analogue inputs: | 1 |
Number of digital outputs: | 0 |
Number of digital inputs: | 4 |
With control element: | no |
Application in industrial area permitted: | yes |
Application in domestic- and commercial area permitted: | yes |
Supporting protocol for TCP/IP: | no |
Supporting protocol for PROFIBUS: | no |
Supporting protocol for CAN: | yes |
Supporting protocol for INTERBUS: | no |
Supporting protocol for ASI: | no |
Supporting protocol for KNX: | no |
Supporting protocol for Modbus: | yes |
Supporting protocol for Data-Highway: | no |
Supporting protocol for DeviceNet: | no |
Supporting protocol for SUCONET: | no |
Supporting protocol for LON: | no |
Supporting protocol for PROFINET IO: | no |
Supporting protocol for PROFINET CBA: | no |
Supporting protocol for SERCOS: | no |
Supporting protocol for Foundation Fieldbus: | no |
Supporting protocol for EtherNet/IP: | yes |
Supporting protocol for AS-Interface Safety at Work: | no |
Supporting protocol for DeviceNet Safety: | no |
Supporting protocol for INTERBUS-Safety: | no |
Supporting protocol for PROFIsafe: | no |
Supporting protocol for SafetyBUS p: | no |
Supporting protocol for BACnet: | no |
Supporting protocol for other bus systems: | yes |
Number of HW-interfaces industrial Ethernet: | 0 |
Number of interfaces PROFINET: | 0 |
Number of HW-interfaces RS-232: | 0 |
Number of HW-interfaces RS-422: | 0 |
Number of HW-interfaces RS-485: | 1 |
Number of HW-interfaces serial TTY: | 0 |
Number of HW-interfaces USB: | 0 |
Number of HW-interfaces parallel: | 0 |
Number of HW-interfaces other: | 0 |
With optical interface: | no |
With PC connection: | yes |
Integrated breaking resistance: | no |
4-quadrant operation possible: | no |
Type of converter: | U converter |
Degree of protection (IP): | IP20 |
Height: | 230 mm |
Width: | 45 mm |
Depth: | 169 mm |
Degree of protection (NEMA): | Other |
Buy online
Wholesalers below does not have this product in their warehouses. You can anyway contact them and order it.
Order
Wholesaler
Address
Distance
Actions
Gniezno,
ul. Słoneczna 40a
Distance:
Szaflary,
ul. Zakopiańska 18
Distance:
Limanowa,
ul. Tarnowska 9D
Distance:
Additional information:
Information | Value |
---|---|
Updated: | 2024-09-23 00:03:47 |
Files to download: |
|
External links: |