DA1-34240FB-B55C Przemiennik 132kW 3x400V RFI IP55 OLED lak.
Information | Value |
---|---|
Supplier | EATON Electric Sp. z o.o. (MOELLER) |
Symbol | 169407 |
GTIN(EAN) | 4015081658473 |
Price unit | piece |
Catalog price | 59 839,50 zł (48 650,00 zł + 23% VAT) |
The given prices do not constitute an offer within the meaning of the Civil Code. The purchase prices of a given item may differ from those displayed.
Description:
Variable frequency drives featuring fast and easy commissioning, compact dimensions, easy mounting (DIN-rail mounting and panel mounting), vector control, STO (Safe Torque Off), integrated LCD display, optional OLED display, CANopen and Modbus on board, integrated EMC filter and brake chopper, integrated PID controller, integrated PLC, simple PC parameterization using drivesConnect parameter software
Additional features:
Information | Value |
---|---|
Net weight: | 80 kg |
Country of origin | Wielka Brytania |
ETIM class: | Frequency converter =< 1 kV |
Width: | 330 mm |
Height: | 1280 mm |
Depth: | 341 mm |
Power consumption: | 2376 W |
With control element: | yes |
Number of digital inputs: | 5 |
Number of digital outputs: | 2 |
Number of analogue inputs: | 2 |
Number of analogue outputs: | 2 |
Supporting protocol for LON: | no |
Number of HW-interfaces industrial Ethernet: | 0 |
Number of HW-interfaces RS-232: | 0 |
Number of HW-interfaces RS-422: | 0 |
Number of HW-interfaces RS-485: | 1 |
Number of HW-interfaces serial TTY: | 0 |
Number of HW-interfaces USB: | 0 |
Number of HW-interfaces parallel: | 0 |
Number of HW-interfaces other: | 0 |
With optical interface: | no |
Supporting protocol for TCP/IP: | yes |
Supporting protocol for ASI: | no |
Supporting protocol for PROFIBUS: | yes |
Supporting protocol for CAN: | yes |
Supporting protocol for INTERBUS: | no |
Supporting protocol for KNX: | no |
Supporting protocol for Modbus: | yes |
Supporting protocol for Data-Highway: | no |
Supporting protocol for DeviceNet: | yes |
Supporting protocol for SUCONET: | no |
Supporting protocol for other bus systems: | yes |
Degree of protection (IP): | IP55 |
With PC connection: | yes |
Supporting protocol for SERCOS: | no |
Supporting protocol for INTERBUS-Safety: | no |
Mains voltage: | 380 - 480 V |
Mains frequency: | 50/60 Hz |
4-quadrant operation possible: | yes |
Number of interfaces PROFINET: | 0 |
Type of converter: | U converter |
Number of phases output: | 3 |
Number of phases input: | 3 |
Integrated breaking resistance: | yes |
Application in industrial area permitted: | yes |
Application in domestic- and commercial area permitted: | yes |
Max. output frequency: | 500 Hz |
Max. output at linear load at rated output voltage: | 132 kW |
Max. output at quadratic load at rated output voltage: | 132 kW |
Relative symmetric net voltage tolerance: | 10 % |
Relative symmetric net frequency tolerance: | 10 % |
Supporting protocol for AS-Interface Safety at Work: | no |
Supporting protocol for DeviceNet Safety: | no |
Supporting protocol for EtherNet/IP: | yes |
Supporting protocol for Foundation Fieldbus: | no |
Supporting protocol for PROFINET CBA: | no |
Supporting protocol for PROFINET IO: | yes |
Supporting protocol for PROFIsafe: | no |
Supporting protocol for SafetyBUS p: | no |
Max. output voltage: | 500 V |
Nominal output current I2N: | 240 A |
Supporting protocol for BACnet: | no |
Degree of protection (NEMA): | 12 |
Buy online
Wholesalers below does not have this product in their warehouses. You can anyway contact them and order it.
Order
Wholesaler
Address
Distance
Actions
Gniezno,
ul. Słoneczna 40a
Distance:
Szaflary,
ul. Zakopiańska 18
Distance:
Limanowa,
ul. Tarnowska 9D
Distance:
Additional information:
Information | Value |
---|---|
Updated: | 2024-12-05 19:45:12 |
Files to download: | |
External links: |