MSC-D-16-M15(230V50HZ) Układ rozruchu, bezpośredniego
Information | Value |
---|---|
Supplier | EATON Electric Sp. z o.o. (MOELLER) |
Symbol | 100414 |
GTIN(EAN) | 4015081003914 |
Price unit | piece |
Catalog price | 1 076,00 zł (874,80 zł + 23% VAT) |
The given prices do not constitute an offer within the meaning of the Civil Code. The purchase prices of a given item may differ from those displayed.
Description:
Wstępnie zmontowany rozrusznik silnika z minimalnym czasem okablowania składający się wyłącznika silnikowego i stycznika.
Additional features:
Information | Value |
---|---|
Net weight: | 589 g |
ETIM class: | Motor starter/motor starter combination |
Width: | 45 mm |
Height: | 180 mm |
Depth: | 95 mm |
With transformer: | no |
Rated operation power at AC-3, 400 V: | 7.5 kW |
Number of command positions: | 0 |
Number of auxiliary contacts as normally open contact: | 1 |
Number of auxiliary contacts as normally closed contact: | 0 |
Suitable for emergency stop: | no |
Rated operation current Ie: | 15.2 A |
Number of indicator lights: | 0 |
Overload release current setting: | 10 - 16 A |
Supporting protocol for LON: | no |
Supporting protocol for TCP/IP: | no |
Supporting protocol for ASI: | no |
Supporting protocol for PROFIBUS: | no |
Supporting protocol for CAN: | no |
Supporting protocol for INTERBUS: | no |
Supporting protocol for Modbus: | no |
Supporting protocol for Data-Highway: | no |
Supporting protocol for DeviceNet: | no |
Supporting protocol for SUCONET: | no |
Supporting protocol for other bus systems: | no |
External reset possible: | no |
Rail mounting possible: | no |
Rated control supply voltage AC 50 Hz: | 230 - 230 V |
Rated control supply voltage AC 60 Hz: | 0 - 0 V |
Rated control supply voltage DC: | 0 - 0 V |
Degree of protection (IP): | IP20 |
Supporting protocol for SERCOS: | no |
Supporting protocol for INTERBUS-Safety: | no |
Release class: | CLASS 10 A |
With short-circuit release: | yes |
With fuse: | no |
Type of electrical connection of main circuit: | Screw connection |
Type of electrical connection for auxiliary- and control current circuit: | Screw connection |
Supporting protocol for AS-Interface Safety at Work: | no |
Supporting protocol for DeviceNet Safety: | no |
Supporting protocol for EtherNet/IP: | no |
Supporting protocol for Foundation Fieldbus: | no |
Supporting protocol for PROFINET CBA: | no |
Supporting protocol for PROFINET IO: | no |
Supporting protocol for PROFIsafe: | no |
Supporting protocol for SafetyBUS p: | no |
Voltage type for actuating: | AC |
Type of motor starter: | Direct online starter (DOL) |
Rated operation power at AC-3, 230 V, 3-phase: | 4 kW |
Rated power, 460 V, 60 Hz, 3-phase: | 0 kW |
Rated power, 575 V, 60 Hz, 3-phase: | 0 kW |
Rated operation current at AC-3, 400 V: | 15 A |
Ambient temperature, upper operating limit: | 55 °C |
Temperature compensated overload protection: | yes |
Rated conditional short-circuit current, type 2, 400 V: | 50 A |
Rated conditional short-circuit current, type 2, 230 V: | 0 A |
Rated conditional short-circuit current, type 1, 480 Y/277 V: | 0 A |
Rated conditional short-circuit current, type 1, 600 Y/347 V: | 0 A |
Degree of protection (NEMA): | Other |
Coordination class according to IEC 60947-4-3: | Class 1 |
Buy online
Wholesalers below does not have this product in their warehouses. You can anyway contact them and order it.
Order
Wholesaler
Address
Distance
Actions
Szaflary,
ul. Zakopiańska 18
Distance:
Limanowa,
ul. Tarnowska 9D
Distance:
Gniezno,
ul. Słoneczna 40a
Distance:
Additional information:
Information | Value |
---|---|
Updated: | 2024-09-23 00:03:12 |
Files to download: |
|
External links: |