Kontroler ruchu M262 3ns/inst 8 Ax Et. S3
Information | Value |
---|---|
Supplier | Schneider Electric Polska Sp. z o.o. |
Symbol | TM262M25MESS8T |
GTIN(EAN) | 3606489604219 |
Price unit | piece |
Catalog price | 16 053,96 zł (13 052,00 zł + 23% VAT) |
The given prices do not constitute an offer within the meaning of the Civil Code. The purchase prices of a given item may differ from those displayed.
Additional features:
Information | Value |
---|---|
Gross weight: | 850 g |
ETIM class: | PLC CPU-module |
Number of digital inputs: | 4 |
Suitable for safety functions: | yes |
Number of digital outputs: | 4 |
Number of analogue inputs: | 0 |
Number of analogue outputs: | 0 |
Supporting protocol for LON: | no |
Radio standard WLAN 802.11: | no |
Radio standard Bluetooth: | no |
IO link master: | no |
Explosion safety category for dust: | None |
Width: | 125 mm |
Model: | Modular |
Processing time (1K, binary operation): | 0.003 ms |
Radio standard GPRS: | no |
Radio standard GSM: | no |
Explosion safety category for gas: | None |
Radio standard UMTS: | no |
Performance level according to EN ISO 13849-1: | None |
Wall mounting/direct mounting: | yes |
Supporting protocol for SUCONET: | no |
Supporting protocol for other bus systems: | yes |
Memory size: | 125000 kB |
With display: | no |
Rack-assembly possible: | yes |
Supply voltage DC: | 20.4 - 28.8 V |
Supporting protocol for KNX: | no |
Supporting protocol for Data-Highway: | no |
Front built-in possible: | no |
Supporting protocol for Modbus: | yes |
Supporting protocol for DeviceNet: | no |
Rail mounting possible: | yes |
Supporting protocol for TCP/IP: | yes |
Appendant operation agent (Ex ib): | no |
Supporting protocol for PROFIBUS: | no |
Supporting protocol for ASI: | no |
Supporting protocol for INTERBUS: | no |
Supporting protocol for CAN: | no |
Appendant operation agent (Ex ia): | no |
Supporting protocol for IEC 61850 Ethernet: | no |
Depth: | 100.5 mm |
Supporting protocol for AS-Interface Safety at Work: | no |
Supporting protocol for PROFINET CBA: | no |
Supporting protocol for Foundation Fieldbus: | no |
Supporting protocol for EtherNet/IP: | yes |
Voltage type (supply voltage): | DC |
Supporting protocol for SafetyBUS p: | no |
Type of memory: | RAM |
Supporting protocol for PROFIsafe: | no |
Long-Term Evolution (LTE): | no |
Supporting protocol for PROFINET IO: | no |
Supporting protocol for DeviceNet Safety: | no |
Supporting protocol for IEC 60870: | no |
Supporting protocol for DNP3: | no |
Redundancy: | no |
Supporting protocol for INTERBUS-Safety: | no |
Height: | 100 mm |
Number of relay outputs: | 0 |
Number of HW-interfaces RS-485: | 1 |
Number of HW-interfaces RS-422: | 0 |
Number of HW-interfaces USB: | 1 |
Number of HW-interfaces other: | 0 |
Number of HW-interfaces wireless: | 0 |
System accessory: | no |
Number of HW-interfaces parallel: | 0 |
Number of interfaces PROFINET: | 0 |
Supporting protocol for SERCOS: | yes |
Additional program memory possible: | yes |
Max. number of time switches: | 0 |
With optical interface: | no |
SIL according to IEC 61508: | None |
Number of HW-interfaces RS-232: | 1 |
Number of HW-interfaces industrial Ethernet: | 2 |
Unfortunately, this product is not available in any warehouse of any wholesaler of the EL-Plus group. However, you can contact the wholesaler of your choice and order it.
Order
Wholesaler
Address
Distance
Actions
Limanowa,
ul. Tarnowska 9D
Distance:
Szaflary,
ul. Zakopiańska 18
Distance:
Gniezno,
ul. Słoneczna 40a
Distance:
Additional information:
Information | Value |
---|---|
Updated: | 2024-09-23 00:05:02 |
Files to download: |
|
External links: |