DM1-121D6EB-S20S-EM DM1Pro | 1-faz./3-faz.230V | 0.25/0.55 kW (1.6/3 A) | rozmiar FS1 | IP20
Information | Value |
---|---|
Supplier | EATON Electric Sp. z o.o. (MOELLER) |
Symbol | 3-5045-004A |
GTIN(EAN) | 4015081980642 |
Price unit | piece |
Catalog price | 2 025,81 zł (1 647,00 zł + 23% VAT) |
The given prices do not constitute an offer within the meaning of the Civil Code. The purchase prices of a given item may differ from those displayed.
Additional features:
Information | Value |
---|---|
Net weight: | 1,2 kg |
Country of origin | Dominikana |
ETIM class: | Frequency converter =< 1 kV |
Mains voltage: | 200 - 240 V |
Mains frequency: | 50/60 Hz |
Number of phases input: | 1 |
Number of phases output: | 3 |
Max. output frequency: | 400 Hz |
Max. output voltage: | 240 V |
Nominal output current I2N: | 1.6 A |
Max. output at quadratic load at rated output voltage: | 0.37 kW |
Max. output at linear load at rated output voltage: | 0.18 kW |
Power consumption: | 31 W |
Relative symmetric net frequency tolerance: | 10 % |
Relative symmetric net voltage tolerance: | 10 % |
Number of analogue outputs: | 1 |
Number of analogue inputs: | 1 |
Number of digital outputs: | 0 |
Number of digital inputs: | 4 |
With control element: | yes |
Application in industrial area permitted: | yes |
Application in domestic- and commercial area permitted: | yes |
Supporting protocol for TCP/IP: | yes |
Supporting protocol for PROFIBUS: | yes |
Supporting protocol for CAN: | yes |
Supporting protocol for INTERBUS: | no |
Supporting protocol for ASI: | no |
Supporting protocol for KNX: | no |
Supporting protocol for Modbus: | yes |
Supporting protocol for Data-Highway: | no |
Supporting protocol for DeviceNet: | no |
Supporting protocol for SUCONET: | no |
Supporting protocol for LON: | no |
Supporting protocol for PROFINET IO: | no |
Supporting protocol for PROFINET CBA: | no |
Supporting protocol for SERCOS: | no |
Supporting protocol for Foundation Fieldbus: | no |
Supporting protocol for EtherNet/IP: | yes |
Supporting protocol for AS-Interface Safety at Work: | no |
Supporting protocol for DeviceNet Safety: | no |
Supporting protocol for INTERBUS-Safety: | no |
Supporting protocol for PROFIsafe: | no |
Supporting protocol for SafetyBUS p: | no |
Supporting protocol for BACnet: | yes |
Supporting protocol for other bus systems: | yes |
Number of HW-interfaces industrial Ethernet: | 1 |
Number of interfaces PROFINET: | 0 |
Number of HW-interfaces RS-232: | 0 |
Number of HW-interfaces RS-422: | 0 |
Number of HW-interfaces RS-485: | 1 |
Number of HW-interfaces serial TTY: | 0 |
Number of HW-interfaces USB: | 0 |
Number of HW-interfaces parallel: | 0 |
Number of HW-interfaces other: | 1 |
With optical interface: | no |
With PC connection: | yes |
Integrated breaking resistance: | yes |
4-quadrant operation possible: | yes |
Type of converter: | U converter |
Degree of protection (IP): | IP20 |
Degree of protection (NEMA): | Other |
Height: | 152 mm |
Width: | 72 mm |
Depth: | 180 mm |
Unfortunately, this product is not available in any warehouse of any wholesaler of the EL-Plus group. However, you can contact the wholesaler of your choice and order it.
Order
Wholesaler
Address
Distance
Actions
Szaflary,
ul. Zakopiańska 18
Distance:
Gniezno,
ul. Słoneczna 40a
Distance:
Limanowa,
ul. Tarnowska 9D
Distance:
Additional information:
Information | Value |
---|---|
Updated: | 2024-12-05 20:14:34 |
Files to download: | |