EU2E-SWD-2DX Moduł IP67 - 2 we cyfrowe SmartWire-DT
Information | Value |
---|---|
Supplier | EATON Electric Sp. z o.o. (MOELLER) |
Symbol | 174725 |
GTIN(EAN) | 4015081712113 |
Price unit | piece |
Catalog price | 923,48 zł (750,80 zł + 23% VAT) |
The given prices do not constitute an offer within the meaning of the Civil Code. The purchase prices of a given item may differ from those displayed.
Additional features:
Information | Value |
---|---|
Net weight: | 85 g |
ETIM class: | Fieldbus, decentr. periphery - digital I/O module |
Supply voltage AC 50 Hz: | 0 - 0 V |
Supply voltage AC 60 Hz: | 0 - 0 V |
Supply voltage DC: | 0 - 28.8 V |
Voltage type (supply voltage): | DC |
Number of digital inputs: | 2 |
Number of digital outputs: | 0 |
Digital inputs configurable: | no |
Digital outputs configurable: | no |
Input current at signal 1: | 4 mA |
Permitted voltage at input: | 20.4 - 28.8 V |
Type of voltage (input voltage): | DC |
Type of digital output: | None |
Output current: | 0 A |
Permitted voltage at output: | 20.4 - 28.8 V |
Type of output voltage: | DC |
Short-circuit protection, outputs available: | no |
Number of HW-interfaces industrial Ethernet: | 0 |
Number of interfaces PROFINET: | 0 |
Number of HW-interfaces RS-232: | 0 |
Number of HW-interfaces RS-422: | 0 |
Number of HW-interfaces RS-485: | 0 |
Number of HW-interfaces serial TTY: | 0 |
Number of HW-interfaces parallel: | 0 |
Number of HW-interfaces wireless: | 0 |
Number of HW-interfaces USB: | 0 |
Number of HW-interfaces other: | 0 |
With optical interface: | no |
Supporting protocol for TCP/IP: | no |
Supporting protocol for PROFIBUS: | no |
Supporting protocol for CAN: | no |
Supporting protocol for INTERBUS: | no |
Supporting protocol for ASI: | no |
Supporting protocol for KNX: | no |
Supporting protocol for Modbus: | no |
Supporting protocol for Data-Highway: | no |
Supporting protocol for DeviceNet: | no |
Supporting protocol for SUCONET: | no |
Supporting protocol for LON: | no |
Supporting protocol for PROFINET IO: | no |
Supporting protocol for PROFINET CBA: | no |
Supporting protocol for SERCOS: | no |
Supporting protocol for Foundation Fieldbus: | no |
Supporting protocol for EtherNet/IP: | no |
Supporting protocol for AS-Interface Safety at Work: | no |
Supporting protocol for DeviceNet Safety: | no |
Supporting protocol for INTERBUS-Safety: | no |
Supporting protocol for PROFIsafe: | no |
Supporting protocol for SafetyBUS p: | no |
Supporting protocol for other bus systems: | yes |
Radio standard Bluetooth: | no |
Radio standard WLAN 802.11: | no |
Radio standard GPRS: | no |
Radio standard GSM: | no |
Radio standard UMTS: | no |
IO link master: | no |
System accessory: | yes |
Degree of protection (IP): | IP69K |
Type of electric connection: | Screw connection |
Time delay at signal change: | 0 - 0.2 ms |
Fieldbus connection over separate bus coupler possible: | yes |
Rail mounting possible: | yes |
Wall mounting/direct mounting: | yes |
Front built-in possible: | no |
Rack-assembly possible: | no |
Suitable for safety functions: | no |
SIL according to IEC 61508: | None |
Performance level according to EN ISO 13849-1: | None |
Appendant operation agent (Ex ia): | no |
Appendant operation agent (Ex ib): | no |
Explosion safety category for gas: | None |
Explosion safety category for dust: | None |
Width: | 56.9 mm |
Height: | 20.1 mm |
Depth: | 98 mm |
Buy online
Wholesalers below does not have this product in their warehouses. You can anyway contact them and order it.
Order
Wholesaler
Address
Distance
Actions
Gniezno,
ul. Słoneczna 40a
Distance:
Szaflary,
ul. Zakopiańska 18
Distance:
Limanowa,
ul. Tarnowska 9D
Distance:
Additional information:
Information | Value |
---|---|
Updated: | 2024-09-23 00:03:43 |
Files to download: | |
External links: |