DA1-345D8FB-A20C Przemiennik 2,2kW 3x400V RFI IP20 lak.
Information | Value |
---|---|
Supplier | EATON Electric Sp. z o.o. (MOELLER) |
Symbol | 169051 |
GTIN(EAN) | 4015081655427 |
Price unit | piece |
Catalog price | 3 375,12 zł (2 744,00 zł + 23% VAT) |
The given prices do not constitute an offer within the meaning of the Civil Code. The purchase prices of a given item may differ from those displayed.
Description:
Variable frequency drives featuring fast and easy commissioning, compact dimensions, easy mounting (DIN-rail mounting and panel mounting), vector control, STO (Safe Torque Off), integrated LCD display, optional OLED display, CANopen and Modbus on board, integrated EMC filter and brake chopper, integrated PID controller, integrated PLC, simple PC parameterization using drivesConnect parameter software
Additional features:
Information | Value |
---|---|
Net weight: | 1,8 kg |
ETIM class: | Frequency converter =< 1 kV |
Mains voltage: | 380 - 480 V |
Mains frequency: | 50/60 Hz |
Number of phases input: | 3 |
Number of phases output: | 3 |
Max. output frequency: | 500 Hz |
Max. output voltage: | 500 V |
Nominal output current I2N: | 5.8 A |
Max. output at quadratic load at rated output voltage: | 2.2 kW |
Max. output at linear load at rated output voltage: | 2.2 kW |
Relative symmetric net frequency tolerance: | 10 % |
Relative symmetric net voltage tolerance: | 10 % |
Number of analogue outputs: | 2 |
Number of analogue inputs: | 2 |
Number of digital outputs: | 2 |
Number of digital inputs: | 5 |
With control element: | yes |
Application in industrial area permitted: | yes |
Application in domestic- and commercial area permitted: | yes |
Supporting protocol for TCP/IP: | yes |
Supporting protocol for PROFIBUS: | yes |
Supporting protocol for CAN: | yes |
Supporting protocol for INTERBUS: | no |
Supporting protocol for ASI: | no |
Supporting protocol for KNX: | no |
Supporting protocol for Modbus: | yes |
Supporting protocol for Data-Highway: | no |
Supporting protocol for DeviceNet: | yes |
Supporting protocol for SUCONET: | no |
Supporting protocol for LON: | no |
Supporting protocol for PROFINET IO: | yes |
Supporting protocol for PROFINET CBA: | no |
Supporting protocol for SERCOS: | no |
Supporting protocol for Foundation Fieldbus: | no |
Supporting protocol for EtherNet/IP: | yes |
Supporting protocol for AS-Interface Safety at Work: | no |
Supporting protocol for DeviceNet Safety: | no |
Supporting protocol for INTERBUS-Safety: | no |
Supporting protocol for PROFIsafe: | no |
Supporting protocol for SafetyBUS p: | no |
Supporting protocol for BACnet: | no |
Supporting protocol for other bus systems: | yes |
Number of HW-interfaces industrial Ethernet: | 0 |
Number of interfaces PROFINET: | 0 |
Number of HW-interfaces RS-232: | 0 |
Number of HW-interfaces RS-422: | 0 |
Number of HW-interfaces RS-485: | 1 |
Number of HW-interfaces serial TTY: | 0 |
Number of HW-interfaces USB: | 0 |
Number of HW-interfaces parallel: | 0 |
Number of HW-interfaces other: | 0 |
With optical interface: | no |
With PC connection: | yes |
Integrated breaking resistance: | yes |
4-quadrant operation possible: | yes |
Type of converter: | U converter |
Degree of protection (IP): | IP20 |
Degree of protection (NEMA): | Other |
Height: | 231 mm |
Width: | 107 mm |
Depth: | 186 mm |
Buy online
Wholesalers below does not have this product in their warehouses. You can anyway contact them and order it.
Order
Wholesaler
Address
Distance
Actions
Limanowa,
ul. Tarnowska 9D
Distance:
Gniezno,
ul. Słoneczna 40a
Distance:
Szaflary,
ul. Zakopiańska 18
Distance:
Additional information:
Information | Value |
---|---|
Updated: | 2024-09-23 00:03:34 |
Files to download: |
|
External links: |